2 Line digital display of rate per acre,
speed, distance, field volume, total volume, field area, total
area, volume per minute, percent application error, time, date.
Retains memory when disconnected from battery.
Retains application data (field volume,
field area, time, date) for 16 chemicals on 99 fields. 1584 memory
locations.
Simplified distance calibration.
RS232 communications port, applications
under development.
Remote run/hold switch to automatically
put the console into hold when turning.
User friendly step-through programming.
8605
Components
Stepper
Motor Servo Valve
1 Inch Stainless Steel
The precision of the motor allows for pinpoint position
of the valve for
optimum flow control.
A Stepper Motor is a 12 Volt DC Brushless Motor which, when
given a command from the 8605 Controller will move a precise
and repeatable distance-one step is equal to one tenth of
one degree (900 steps full open to full close).
HM860
The HM860 is a general purpose flowmeter. This stainless steel
flowmeter is recommended for herbicides, insecticides, liquid
fertilizer and anhydrous ammonia.
The operating range is 3 to 70 gallons per minute. Maximum pressure
is 400 psi.
Other flowmeters are available for low application rates.
Hub Plate Sensor
The Hub Plate Sensor works on
all implement wheels or non-driven tractor wheels.
Plates for four, five, six, and eight
bolt wheels are available.
Optional radar interface modules are available to connect the
tractor radar system to the 8605 Controller.
Heat Exchanger
For anhydrous ammonia applications is required. The Heat Exchanger
condenses vapor to a liquid to allow accurate measurement and control.
Standard features and options,